Tesla Model 3 + Solis Integration

Reusing a Tesla Model 3 or Model Y high-voltage battery pack (350–410 V nominal) with a Solis three-phase hybrid inverter. The BMS-EV controller emulates the battery protocol Solis expects on its BMS CAN bus.

Short answer. A Tesla Model 3/Y HV pack (nominal 350–410 V, operating 260–410 V) is inside the DC input window of the Solis RHI-3P(5–10)K-HVES-5G (195–800 V) and Solis S6-EH3P (90–500 V). The BMS-EV controller emulates a selectable Pylontech, BYD or Force H2 battery protocol on the Solis BMS CAN port. The 500 V ceiling on the S6-EH3P is compatible with Tesla operating voltages, which never exceed ~410 V at 100% SoC.

What works

Supported inverter models

InverterDC input rangePowerPhaseNotes
Solis RHI-3P5K-HVES-5G195–800 V5 kWThree-phaseFull Tesla range fits
Solis RHI-3P6K-HVES-5G195–800 V6 kWThree-phaseFull Tesla range fits
Solis RHI-3P8K-HVES-5G195–800 V8 kWThree-phaseFull Tesla range fits
Solis RHI-3P10K-HVES-5G195–800 V10 kWThree-phaseFull Tesla range fits
Solis S6-EH3P5K90–500 V5 kWThree-phaseTesla 260–410 V fits
Solis S6-EH3P8K90–500 V8 kWThree-phaseTesla 260–410 V fits
Solis S6-EH3P10K90–500 V10 kWThree-phaseTesla 260–410 V fits

Battery voltage range match

Tesla Model 3/Y HV pack voltages by state of charge:

StateVoltage (approx.)
0% SoC (empty cutoff)~260 V
10% SoC~330 V
50% SoC (nominal)~360 V
100% SoC (full)~403–410 V

The Solis RHI-3P HVES accepts 195–800 V — full Tesla range is inside. The Solis S6-EH3P accepts 90–500 V — Tesla peak (~410 V) is inside the 500 V ceiling. No pack sub-splitting is required.

CAN protocol mapping

Solis hybrid inverters listen on the BMS CAN port for one of several selectable battery protocols. The BMS-EV controller emulates the protocol you set in the Solis local display menu:

The BMS-EV controller reads Tesla's proprietary vehicle CAN messages (SoC, cell voltages min/max, pack current, module temperatures, contactor state, charge/discharge limits) and re-encodes them into the Solis-selected protocol at 500 kbps.

Wiring architecture

┌─────────────────┐ ┌──────────────┐ ┌──────────────────┐ │ Tesla Model 3 │ │ BMS-EV │ │ Solis RHI-3P │ │ HV pack │ │ Controller │ │ or S6-EH3P │ │ (350-410 V) │ │ │ │ │ │ │ CAN │ Protocol │ CAN │ │ │ Tesla BMS kept │─────►│ translator │─────►│ BMS port │ │ │ 500k │ │ 500k │ │ └────┬────────┬───┘ └──────────────┘ └────┬─────────┬───┘ │ HV+ │ HV- │ BAT+ │ BAT- │ │ │ │ └────────┴─────────────────────────────────────┘─────────┘ │ └── main contactors + precharge + HV fuse (installer)

Installation requirements

Engineering values below are examples. Final conductor cross-section and protective-device sizing must be calculated for the actual pack, maximum current, cable length, installation method, ambient temperature and applicable local standards (IEC 60364-7-712, VDE-AR-N 4105, NEC 690).

Known limitations

FAQ

Can I use the Solis RHI-3P with a 100% charged Tesla pack?

Yes. Tesla's 100% SoC corresponds to ~403–410 V, well below the Solis RHI-3P 800 V ceiling and below the S6-EH3P 500 V ceiling.

Which Solis protocol should I select in the menu?

Pylontech is the recommended default — it is the most stable across Solis firmware revisions. BYD Premium HV is an alternative if you need higher discharge current limits. The BMS-EV controller is pre-configured to match whatever you select.

Do I need to open the Tesla pack?

No. The pack is used as a complete unit. HV+ and HV- are taken from the factory HV service disconnect location. The pack's BMS remains inside and continues to handle balancing and cell protection.

What happens if the Solis inverter loses CAN communication?

Solis firmware raises a battery communication fault after ~30 seconds of missing frames and stops charging/discharging. The Tesla BMS then opens its contactors on the standard idle timeout (typically 5 minutes). Restarting the BMS-EV controller re-establishes both.

Can I run two Tesla packs in parallel on one Solis?

Not directly — parallel packs must be voltage-matched to within ~2 V before contactor close, which is difficult with two independent Tesla BMSes. For >75 kWh systems, a second Solis and a second controller is the supported approach.

Does the Solis app show SoC correctly?

Yes. The BMS-EV controller maps Tesla's internal SoC (which spans a conservative 0–100% usable window) directly to the Pylontech SoC field the Solis app reads.

Is off-grid / EPS supported?

The Solis RHI-3P HVES has a backup port with UPS-grade transfer time. The BMS-EV controller reports discharge current limits Solis uses to size the backup load in real time.

Do I need Tesla service tools?

No. The BMS-EV controller wakes and drives the Tesla BMS using the same CAN messages the vehicle's VCU would send. Tesla Toolbox is not required for stationary use.

Order a Tesla + Solis BMS-EV controller
Pre-configured firmware, shipped worldwide
Last updated: 2026-09-18
Current firmware: 15.0.14
Technical author: BMS-EV engineering team (Clima Boost sp. z o.o., Poland)
Reviewer: Jakub Lipiński, founder/lead engineer BMS-EV
Revision: 2026-09-18 — aligned with firmware 15.0.14, SOFAR 180–800 V DC verification, Kia EV6 + SOFAR HYD 15KTL case study reference